All Issue

2019 Vol.24, Issue 1 Preview Page

Research Article

30 March 2019. pp. 15-24
Abstract
References
1
NEI, Guidance for Post-Fire Safe-Shutdown Circuit Analysis, Revision 3(draft), Nuclear Energy Institute, 2010.
2
EGM, Enforcement Guidance Memorandum—-Enforcement Discretion for Fire Induced Circuit Faults, 2009, ADAMS Accession No. ML090300446.
3
D.I. Kang, K.Y. Kim, G.Y. Park, Safety Assessment on Multiple Spurious Operations of Fire-Induced Cable Failures and their Effects on Pilot Systems, KAERI, 2011, KAERI/CR-404/2010.
4
D.I. Kang, K.Y. Kim, S.C. Jang, Risk Assessment on the Fire-Induced Spurious Operations of High Pressure Safety Injection System for Domestic Nuclear, J. Kor. Institute of Fire Sci. & Eng., Spring Annual Fall Conference, (2012), 303-306.
5
T.R. Hull, K. Lebek, M. Pezzani, S. Messa, Comparison of Toxic Product Yields of Burning Cables in Bench and Large-Scale Experiments. Fire Safety J., 43(2) (2008) 140-150.
10.1016/j.firesaf.2007.06.004
6
S.K. Lee, Y.S. Moon, S.Y. Yoo, A Study on Validation Methodology of Fire Retardant Performance for Cables in Nuclear Power Plants, J. Korean Soc. Safety, 32(1) (2017) 140-144.
7
A. Witkowski, B. Girardin, M. Forsth, F. Hewitt, G. Fontaine, S. Duquesne, S. Bourbigot, T.R. Hull, Development of an AAnaerobic Pyrolysis Model for Fire Retardant Cable Sheathing Materials, Polym. Degrad. Stab., 113 (2015) 208-217.
10.1016/j.polymdegradstab.2015.01.006
8
T.R. Hull, A.A. Stec, K. Lebek, D. Price, Factors Affecting the Combustion Toxicity of Polymeric Materials. Polym. Degrad. Stab., 92(12) (2007) 2239-2246.
10.1016/j.polymdegradstab.2007.03.032
9
A.A. Stec, T.R. Hull, Assessment of the Fire Toxicity of Building Insulation Materials, Energ. Buildings, 43(2-3) (2011) 498-506.
10.1016/j.enbuild.2010.10.015
10
H.J. Seo, N.K. Kim, J.M. Jo, M.C. Lee, S.K. Lee, Y.S. Moon, A Study on the Human Toxicity of Combustion Products for Non Class 1E Cables, J. Korean Soc. Hazard Mitig., 18(2) (2018) 215-222.
10.9798/KOSHAM.2018.18.2.215
11
H.S. Lim, D.H. Kim, A Study on Heat-Flux Evaluation for Cable Fire Including Diagnostic Methodology for Degradation in Nuclear Power Plants. J. Korean Soc. Safety, 26(2) (2011) 20-25.
12
S.K. Song, A Study on the Combustion Characteristics According to the Aging of Communication Cables and Power Cables, M. S. Thesis, Kangwon National University, Samcheok, 2011.
13
KS F ISO 5660-1, Reaction to Fire Test-Heat Release, Smoke Production and Mass Loss Rate - Part 1 Heat Release Rate (Cone Calorimeter Method), 2008.
14
ISO 19702, Guidance for Sampling and Analysis of Toxic Gases and Vapours in Fire Effluents using Fourier Transform Infrared (FTIR) Spectroscopy, 2015.
15
S.S. Kim, A Study on Complex Risk Assessment for Construction Materials of Fire Effluents, Ph.D. Thesis, Incheon National University, Incheon, 2016.
16
ISO 9122-4, Toxicity Testing of Fire Effluents - Part 4:The Fire Model (Furnaces and Combustion Apparatus used in Small-Scale Testing), 1993.
17
H.J. Seo, W. Hwang, M.C. Lee, Combustion Characteristics of Fire Retardants Treated Domestic Wood, J. Korean Soc. Combust. 22(2) (2017) 14-23.
18
H.J. Seo, J.M. Jo, W. Hwang, M.C. Lee, Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added, J. Korean Soc. Combust. 22(4) (2017) 1-8.
19
T.R. Hull, K. Lebek, M. Pezzani, S. Messa, Comparison of Toxic Product Yields of Burning Cables in Bench and Large-Scale Experiments, Fire Safety J., 43 (2008) 140-150.
10.1016/j.firesaf.2007.06.004
20
S. Mo, J. Zhang, D. Liang, H. Chen, Study on Pyrolysis Characteristics of Cross-Linked Polyethylene Material Cable, Procedia Engineering, 52 (2013) 588–592.
21
Y.I. Mok, A Review of the Flame Retardation of Flammable Polymer, Korean Chem. Eng. Res., 15(4) (1977) 211-224.
22
C. Wang, H. Liu, J. Zhang, S. Yang, Z. Zhang, W. Zhao, Thermal Degradation of Flame-Retarded High-Voltage Cable Sheath and Insulation via TG-FTIR, J. Anal. Appl. Pyrolysis, 134 (2018) 167-175.
10.1016/j.jaap.2018.06.005
23
B.H. Han, D.H. Seo, Y.H. Kwon, S.H. Min, A Study on the Fire Characterization of Foam Block using Cone-Calorimeter and FTIR, J. Korean Inst. Fire Sci. Eng., 31(6) (2017) 23-32.
24
N.K. Kim, Complex Risk Assessment of Combustion Products during in Fire for replacing Animal Experimentation, Department of Safety Engineering, M.S. Thesis, Incheon National University, Incheon, 2018.
25
H.K. Kim, Radiation Ray Stress Characteristics of EPDM Insulation Cable for Nuclear Power Plant, Department of Electrical Engineering, M.S. Thesis, Chosun University, Gwangju, 2002.
26
I.K. Sung, Studies in Physical Properties and Flame Reratardance of Rubber Blend Mixtures Containing Flame Retardant, Department of Polymer Engineering, Ph.D. Thesis, Pukyong National University, Busan, 2017.
27
D. Tabuani, F. Bellucci, A. Terenzi, G. Camino, Flame Retarded Thermoplastic Polyurethane (TPU) for Cable Jacketing Application, Polym. Degrad. Stab., 97 (2012) 2594-2601.
10.1016/j.polymdegradstab.2012.07.011
Information
  • Publisher :The Korean Society Combustion
  • Publisher(Ko) :한국연소학회
  • Journal Title :Journal of The Korean Society Combustion
  • Journal Title(Ko) :한국연소학회지
  • Volume : 24
  • No :1
  • Pages :15-24
  • Received Date : 2018-08-24
  • Revised Date : 2018-10-26
  • Accepted Date : 2018-11-02